CBWMN - MS-50, HARDENER COMPONENT

Product Identification

Product ID:MS-50, HARDENER COMPONENT
MSDS Date:05/08/1991
FSC:8010
NIIN:00N067108
Kit Part:Y
MSDS Number: CBWMN

Responsible Party
AMERICAN SAFETY TECHNOLOGIES INC
565 EAGLE ROCK AVE
ROSELAND, NJ 07068
US

Emergency Phone: 800-424-9300(CHEMTREC)

Info Phone: 201-403-2600

Preparer: F. LOELOFF

Cage: AMSAT

Contractor
AMERICAN SAFETY TECHNOLOGIES INC.
ROSELAND, NJ 07068 US

Telephone: 800-424-9300

Cage: AMSAT

Ingredients

POLYAMIDE RESIN

CAS: 68410-23-1

OSHA PEL N/K

ACGIH TLV: N/K


BUTYL ALCOHOL

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: 20.0%

OSHA PEL N/K

ACGIH TLV: N/K

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


1,2-ETHANEDIAMINE, N-(2-AMINOETHYL)-N'-(2-((-

CAS: 112-57-2

RTECS: KH8585000

Fraction By Weight: 4.0%

OSHA PEL N/K

ACGIH TLV: N/K

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:EYES:CAUSES SEVERE IRRITATION OR
BURNS. MAY CAUSE PERMANENT VISUAL IMPAIRMENT. SKIN:CAUSES SEVERE
IRRITATION OR BURNS. MAY BE ABSORBED THROUGH THE SKIN IN HARMFUL
AMOUNTS. INHALATION:MAY CAUSE UPPER R ESPIRATORY TRACT IRRITATION.
INGESTION:MAY CAUSE BURNS OF MOUTH AND THROAT. CONTAINS MATERIAL
THAT MAY BE SLIGHTLY TOX.
Explanation of Carcinogenicity:NOT RELEVANT
Effects of Overexposure:IRRITATION, SENSITIZATION AND DERMATITIS.
Medical Cond Aggravated by Exposure:ALLERGY, ECZEMA AND OTHER SKIN
CONDITIONS.

First Aid

First Aid:EYES:FLUSH WITH LARGE AMOUNTS OF WATER FOR AT LEAST 15
MINUTES. GET MEDICAL ATTENTION. SKIN:REMOVE CONTAMINATED CLOTHING.
WASH CONTACT AREA WITH MILD SOAP AND WATER FOR 15 MINUTES.
INHALATION:REMOVE T O FRESH AIR. IF SYMPTOMS PERSIST CONSULT A
PHYSICIAN. INGESTION:DO NOT INDUCE VOMITING. IF CONSCIOUS, GIVE
LARGE QUANTITIES OF WATER TO DILUTE. GET MEDICAL ATTENTION.

Fire Fighting

Flash Point Method:PMCC
Flash Point:>100F,>38C
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, CHEMICAL FOAM OR
WATER.
Fire Fighting Procedures:WEAR NIOSH/MSHA APPROVED SCBA & FULL
PROTECTIVE EQUIPMENT . REMOVE ALL IGNITION SOURCES.
Unusual Fire/Explosion Hazard:DECOMPOSITION AND COMBUSTION PRODUCTS MAY
BE TOXIC.

Accidental Release

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. DIKE SPILL.
ABSORB WITH INERT MATERIAL AND COLLECT FOR DISPOSAL. FLUSH
CONTAMINATED AREA WITH WATER; PREVENT WASHINGS FROM ENTERING
WATERWAYS.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:AVOID ALL PERSONAL CONTACT. DO NOT
EXCEED 110F/43C IN STORAGE AREA. GROUND AND BOND METAL CONTAINERS
FOR LIQUID TRANSFER TO AVOID STATIC SPARKS.
Other Precautions:NONE SPECIFIED BY MANUFACTURER.

Exposure Controls

Respiratory Protection:NIOSH/MSHA APPROVED RESPIRATOR WITH ORGANIC
VAPOR CARTRIDGE IF REQUIRED.
Ventilation:EXPLO-PROOF MECH VENT & LOC EXHST ARE REC. MECH EXHST IS
NOT REC AS SOLE MEANS OF CONTROLLING EMPLOYEE EXPOSURE.
Protective Gloves:IMPERVIOUS GLOVES.
Eye Protection:ANSI APPROVED CHEM WORKERS GOGGS .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
IN OPERATIONS WHERE CONT MAY OCCUR, COVERALLS, APRON AND (SUPP
DATA)
Work Hygienic Practices:CONTAMINATED CLOTHING SHOULD BE REMOVED
IMMEDIATELY AND THOROUGHLY LAUNDERED BEFORE REUSE.
Supplemental Safety and Health
OTHER PROT EQUIP:IMPERVIOUS FOOT COVERING ARE RECOMMENDED.

Chemical Properties

Spec Gravity:0.96
Solubility in Water:PARTIALLY SOLUBLE
Appearance and Odor:AMBER LIQUID, SOLVENT ODOR.

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS.
Stability Condition to Avoid:EXCESSIVE HEAT.
Hazardous Decomposition Products:CARBON MONOXIDE, CARBON DIOXIDE,
ALDEHYDES AND OXIDES OF NITROGEN.

Disposal

Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE &
LOCAL REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.